[output energy] = takanen2013wbmso(ipsilateral, contralateral, fs, widthinerbs, fc, printfigs)
ipsilateral | The ipsilateral "where" stream output from the model of the periphery |
contralateral | The contralateral "where" stream output from the model of the periphery |
fs | Sampling rate |
widthinerbs | The number of adjacent ERB bands the information is gathered over |
fc | Characteristic frequencies |
printFigs | Boolean value that defines whether several figures illustrating the processing steps in the model are plotted or not. As default, no figures are plotted. |
output | Spatial cues for frequency bands that are summed together to form a width defined by widthinerbs |
energy | "What" stream for the wideband MSO |
The wideband MSO model simulates the ability of the human auditory system to extract localization cues based on interaural envelope time shifts. These time shifts are decoded into directional cues for the model. This is done by processing the output of the periphery model with the following steps:
V. Pulkki and T. Hirvonen. Functional count-comparison model for binaural decoding. Acta Acustica united with Acustica, 95(5):883 - 900, Sept./Oct. 2009.
M. Takanen, O. Santala, and V. Pulkki. Visualization of functional count-comparison-based binaural auditory model output. Hearing research, 309:147-163, 2014. PMID: 24513586. [ DOI ]